Instructions

These instructions are provided for your information and are supplied with each unit sold.

ZHC2 Zapper Frequency Generator Instructions

Disclaimer: Experimental use only. These instructions and the use of this device are not intended to replace the advice of a health care professional. We cannot be responsible for any adverse effects believed to be due to the use of this device.

  1. Plug the copper handholds into the zapper.
  2. Cut strips of paper towelling 90mm (3½") wide. Wind a single layer around each handhold.
  3. Dip each handhold in a glass of water (preferably distilled) and squeeze out excess moisture.
  4. Turn zapper on. The light flashes green to indicate current flow to each handhold.
  5. Grasp one handhold securely in each hand. Do not let your hands touch.
  6. Zap for 7-10 minutes.
  7. After this, switch the unit off for an intermission of 20-30 minutes.
  8. Zap again (with the unit turned on) for another session of 7-10 minutes and an intermission of 20-30 minutes.
  9. Repeat once more, giving 3 sessions altogether.
  10. If the handholds dry out re-wet during your zapping session.
  11. When finished, remove paper towel strips and discard. Polish each handhold with nylon scouring pad (supplied). If handholds become badly tarnished, clean with a stainless steel scouring pad, then wipe clean and repolish. Store handholds in paper bag when not in use.
  12. For further information regarding zapping refer to the book "The Cure For All Diseases" by Hulda R. Clark.

We recommend a 9v alkaline battery (not supplied). When battery is low, the light will change from green to orange-red colour.

  1. Remove the battery cover
  2. Lift battery out and unclip it from it's black snap terminal
  3. Fit new battery and place in the case
  4. Re-fit the cover
  5. Turn the unit on to test. The light should glow green. Turn unit off until next use.

Printer Friendly Version


ZMEG Zapper Instructions

Disclaimer: Experimental use only. These instructions and the use of this device are not intended to replace the advice of a health care professional. We cannot be responsible for any adverse effects believed to be due to the use of this device.

  1. Plug the handholds into the zapper.
  2. Turn zapper on. The light flashes green to indicate current flow to each handhold.
  3. Grasp one handhold securely in each hand. Do not let your hands touch.
  4. Zap for 7-10 minutes.
  5. After this, switch the unit off for an intermission of 20-30 minutes.
  6. Zap again (with the unit turned on) for another session of 7-10 minutes and an intermission of 20-30 minutes.
  7. Repeat once more, giving 3 sessions altogether.
  8. If handholds become dirty, clean with a scouring pad, then wipe clean. Store handholds in paper bag when not in use.
  9. For further information regarding zapping refer to the book "The Cure For All Diseases" by Hulda R. Clark.

We recommend two 9v Heavy Duty batteries. When battery is low, the light will change from green to orange-red colour.

  1. Unscrew 4 screws securing the cover
  2. Gently lever the cover off
  3. Being careful not to damage the circuit board, lift both batteries out and unclip them from their black snap terminals
  4. Fit new batteries and place in the case
  5. Fit the lid and secure with 4 screws
  6. Turn the unit on to test. The light should glow green. Turn unit off until next use.
Back to top

Printer Friendly Version


ZSUP Super Zapper Instructions

Please read and follow all instructions fully before using this device.
Failure to do so may cause adverse reactions.

Disclaimer: Experimental use only. These instructions and the use of this device are not intended to replace the advice of a health care professional. We cannot be responsible for any adverse effects believed to be due to the use of this device.

Locate maximum ulnar and radial pulse positions on left wrist. Clean area with soap and water or alcohol swab.

  1. Fit velcro strap first. Locate the two stainless steel wrist electrodes and insert in cotton sleeves. Position electrodes lengthwise along radial and ulnar arteries respectively (see separate diagram). Hold electrodes securely in place beneath velcro strap.
  2. Using salt and dropper bottle supplied, make up a salt solution with water by adding 1/8 tsp salt to 25 ml water (1 tablespoon). Shake well. Wet electrodes with a few drops of this solution.
  3. Turn on the machine, ensure light flashes and keep the level control to minimum (anticlockwise).
  4. Plug electrode lead into small socket located beside the flashing light. (The light will go out to indicate current flow in the electrodes).
  5. Rotate level control slowly clockwise until you feel a "thumping" and tingling sensation. Turn as high as possible but don't turn up to where it is uncomfortable. Adjust the level periodically as your body adapts to the current after several minutes. It is normal to feel progressively less sensation with time. You may notice little or no sensation at full level immediately, but feeling will begin building up to maximum after several minutes at which time the level must be decreased. Keep electrodes moist by applying a drop of the salt solution every 20 minutes.
  6. Use for 2 hours daily for up to 2 months. Use judgment here - the limiting factor is detoxification. Drink plenty of water. With heavy infections go slower so as not to overload the body's toxic disposal capability. Carefully monitor reactions as deciding factor in how long to apply the current. (There may be detox effects such as skin eruptions, rashes, boils, discomfort, nausea, coated tongue.) Some have used the unit as recommended for weeks. Others benefit from only short sessions (less than 2 hours a day for two months, then have a break for a month, then continue on for another two months and so on). Most viruses etc are killed within 21 days.
  7. After use, carefully unplug the electrodes and machine and store until next use. Wash cotton sleeves in warm water from time to time as necessary.
  1. Drink a 200 ml glass of filtered water 15 minutes before and immediately after each session. Drink at least four more glasses daily for flushing during electrification and for one week after. Failure to do this may cause systemic damage from unflushed toxins.
  2. Battery replacement: The LED (light) flashes only when electrodes are not plugged in. If LED does not flash or has become dim battery will need replacing. Use only 9V alkaline type.
  3. Do not immerse your Super Zapper in water. To clean, wipe case with a damp cloth. For servicing or further information please refer to your supplier, or contact us.
  1. Failure to follow precautions may cause adverse reactions.
  2. Avoid ingesting anything containing medicinal herbs, or potentially toxic medication, nicotine, alcohol, recreational drugs, laxatives, tonics and certain vitamins for one week prior to starting. (Blood electrification increases cell permeability to small quantities of previously harmless chemicals. The effect is similar to overdosing.) When absolutely essential drugs must be taken, do so a few minutes after the electrification, then wait 24 hours before next session, that is, DO NOT TAKE ROUTINE MEDICATION OR HERBS IMMEDIATELY BEFORE YOUR TREATMENT.
  3. Do not place electrodes over skin lesions, abrasions, new scar tissue, cuts, eruptions or sunburn. Do not advance output level to uncomfortable settings. There may be slight reddening of the skin under the electrodes. This is normal.
  4. If you feel sluggish, faint, dizzy, headachey, light-headed, giddy or nauseous, or have flu-like symptoms or rashes after electrification, reduce application time. Drink more water - preferably distilled and ozonised to increase toxin flushing.
  5. Use extreme caution if you have impaired kidney or liver function. Start slowly at first with 20 minutes per day to reduce detox effects.
  6. DO NOT USE THE SUPER ZAPPER IF YOU ARE PREGNANT OR WEAR A PACEMAKER.
  7. DO NOT DRIVE A MOTOR VEHICLE WITHIN 2 HOURS OF USE.

COLLOIDAL SILVER MAKING

  1. Bend the supplied .9999 pure silver wires to fit over the lip of a clean 250 ml 8oz glass tumbler. Fill with purified water and attach colloidal silver lead set to silver wires. These are the red and black clips at one end of a shorter lead.
    The other end has a plug which fits into the side of the silver pulser case. It does not matter which lead goes to which silver wire electrode. DO NOT let silver electrodes touch each other.
  2. If you are using distilled water, put a drop of 1% salt solution into the water. Salt solution may be made by stirring 1/8 teaspoon salt into 25mls (1 tablespoon) water. Store in dropper bottle supplied.
  3. Turn the unit on. Ensure red LED light flashes. (Make sure wrist electrode lead is not plugged in.) The level control does not affect the colloidal silver generation. Four minutes will produce a fine silver colloid solution of 10ppm. You will see plumes of silver coming off one electrode.
  4. Turn the unit off. Unclip the leads and remove the silver wire electrodes from the glass of colloidal silver solution. Polish the silver wire electrodes after use, using a piece of paper toweling or plastic scouring pad. Dry and store for reuse.
  5. Stir the solution and consume immediately or store no longer than 24 hours in a refrigerator.

Printer Friendly Version


CSG1 Colloidal Silver Generator Instructions

  1. Remove battery door.
  2. Install 1 x 9v battery and refit the battery door.
  3. Insert the two silver rods through the holes in the wooden holder so that 1cm protrudes from the top. The silver rods must be parallel, and one inch (2-3cm) apart. Attach an alligator clip to each silver rod.
  4. Fill a glass tumbler almost to the top with (preferably) distilled water. Place the wood block over the top of the tumbler so the silver rods hang down into the water. Make sure they do not touch the sides of the glass. If rods touch the bottom of the glass tumbler, pull the rods up slightly through the holes in the wood block.
  5. Insert the plug into the socket of the Colloidal Silver Generator; the green LED light comes on.
  6. Begin timing (use the timer on the stove set to 20 minutes as a reminder).
  7. After a few minutes mist and bubbles should be seen coming from one of the silver rods. The water will also become slightly cloudy. The positive rod will accumulate a dark grey oxide coating. Sometimes this coating becomes black. If this happens, carefully lift the rods out of the water and wipe clean with a paper towel, then place rods back in the water.
  8. After twenty minutes the colloidal silver should be 5ppm. Another 10-20 minutes will produce 10ppm. When you have finished generating, remove the rods and briefly stir the colloidal silver with a non-metal stirrer.
  9. Unplug the lead from the generator to conserve batteries.
  10. Clean the rods to a shiny finish with a plastic scouring pad before next use.
  11. Your colloidal silver solution should be a grey/gold colour when held up to the light, and have a slight metallic taste.
  12. If any black oxide formed, you can either leave the solution to settle then decanter it, or pass the solution through high quality coffee-filter paper before consuming. (Filter paper is available at coffee shops or supermarkets; use non-bleached paper.)

To make larger quantities of colloidal silver, expect 10 minutes per 100mls of distilled water (e.g. 500mls takes about 50 minutes). You will need to watch more closely in case of black oxide forming. If this happens, remove the rods, clean, and re-insert again.

Colloidal silver may be stored for up to three months in a dark glass container, away from sunlight, not in the fridge, or near electrical appliances.

Replace battery when the LED light changes to a red colour.

Printer Friendly Version